Servo Motor Sizing Calculator — RMS & Peak Torque, Duty Cycle
Estimate servo RMS torque, required peak torque, thermal utilization and inertia ratio from load inertia, gearing, motion timing and candidate motor ratings.
Enter the known values and review the calculated result
Input parameters
Use consistent values and select the intended engineering units.
Transmission and inertia
Motor-shaft motion profile
External and holding torques
Selected motor verification — optional
Results
Calculation tools Save, export and manage your results
Save your calculation, export available results, or store a finalized engineering artifact in your account.
Method, application and limitations
Review the calculation method, intended application and engineering assumptions before using the result in a design decision.
Formula and calculation method
Servo motor sizing equations
This calculator evaluates a repeated servo motion cycle from motor-side speed, load and motor inertia, gear ratio, transmission efficiency, motion times, external torque and candidate motor torque ratings. Its primary results are RMS torque, required peak torque and thermal utilization.
Angular acceleration
The acceleration magnitude is calculated from the entered maximum motor speed and acceleration time:
α = ωmax / tacc
- α — required angular acceleration [rad/s2]
- ωmax — maximum motor-shaft angular speed [rad/s]
- tacc — acceleration time [s]
Reflected inertia and inertia ratio
Load inertia is reflected through the gear ratio by the square of the ratio:
Jload,ref = Jload / i2
The total inertia accelerated by the motor model is:
Jref = Jmotor + Jload / i2
The reported load-to-motor inertia ratio is:
Inertia ratio = (Jload / i2) / Jmotor
- Jload — entered load inertia
- Jmotor — motor rotor plus input-side inertia
- i — motor/load speed ratio
External torque and phase torque
The JavaScript applies transmission efficiency to the external torque as:
Text,eff = Text / η
The phase torques are then calculated as:
Tacc = Jref · α + Text,eff
Tdec = -Jref · α + Text,eff
Tconst = Text,eff
Tidle = 0
The required peak torque is the largest absolute phase torque:
Tpeak,req = max(|Tacc|, |Tdec|, |Tconst|)
RMS torque over the servo duty cycle
Total cycle time is:
tcycle = tacc + tconst + tdec + tidle
Cycle-equivalent RMS torque is:
TRMS = √[(Tacc2tacc + Tconst2tconst + Tdec2tdec + Tidle2tidle) / tcycle]
The RMS value represents the equivalent torque level used by this calculator for continuous thermal screening of the selected motor.
Motor utilization
Thermal utilization = (TRMS / Tnom) · 100%
Peak utilization = (Tpeak,req / Tpeak,motor) · 100%
- Tnom — available continuous motor torque
- Tpeak,motor — available peak motor torque
Motion duty cycle
The reported duty cycle is the fraction of the complete cycle occupied by acceleration, constant-speed motion and deceleration:
DC = [(tacc + tconst + tdec) / tcycle] · 100%
This is a motion-cycle duty factor, not an electrical PWM duty cycle.
Mechanical power indicators
The calculator also reports secondary mechanical-power indicators:
Ppeak = max(|Taccωmax|, |Tconstωmax|, |Tdecωmax|)
ωRMS = √{[ωmax2tacc/3 + ωmax2tconst + ωmax2tdec/3] / tcycle}
PRMS = TRMS · ωRMS
These values are mechanical indicators from the implemented motion model. They are not electrical input-power or drive-loss calculations.
When to use this calculator
When to use this servo motor sizing calculator
Use this calculator for preliminary servo motor sizing when the load inertia, motor inertia, gearing and repeated motion profile are already known. It is particularly useful for evaluating whether a candidate motor has sufficient continuous and peak torque capability for an acceleration-cruise-deceleration cycle.
Typical applications include:
- preliminary servo sizing for indexing and positioning axes;
- checking RMS torque over a repetitive machine cycle;
- calculating required peak torque during acceleration and deceleration;
- comparing RMS torque with the motor continuous torque rating;
- comparing required peak torque with the motor peak torque rating;
- evaluating reflected load inertia through a gearbox or reducer;
- screening the load-to-motor inertia ratio;
- studying the effect of acceleration time, dwell time, gear ratio or external torque on servo loading.
Inputs required by the current solver
The supplied JavaScript requires positive values for load inertia, motor inertia, gear ratio, acceleration time, deceleration time, maximum motor speed, continuous motor torque and peak motor torque.
Constant-speed time and idle time may be zero. External torque defaults to zero when it is not finite. Transmission efficiency defaults to 1 when the supplied value is missing or outside the implemented valid range.
What this calculator does not determine
This is not a complete manufacturer-specific servo selection tool. It does not derive load inertia from mechanism geometry, select a catalog motor, read a motor torque-speed curve, verify drive current or voltage, calculate regenerative energy, model mechanical resonance, or verify control-loop tuning.
The current solver also does not use the provided motor maximum-speed verification field, so maximum permissible motor speed must be checked separately against the motor and drive data.
How to interpret the result
How to interpret the servo sizing results
RMS torque
TRMS is the primary continuous-duty result. Compare it with the continuous torque available from the candidate motor under the actual operating conditions. The calculator expresses this comparison as thermal utilization.
- Thermal utilization = 100% means TRMS equals the entered continuous torque.
- Thermal utilization above 85% triggers the calculator's warning state.
- TRMS greater than the entered continuous torque triggers an invalid result.
Required peak torque
Tpeak,req is the largest absolute torque calculated for acceleration, deceleration or constant-speed operation.
- Peak utilization = 100% means required peak torque equals the entered motor peak torque.
- Peak utilization above 90% triggers a warning.
- Required peak torque greater than the entered motor peak torque triggers an invalid result.
Inertia ratio
The inertia ratio compares reflected load inertia with motor inertia. The current decision logic uses:
- ratio ≤ 10 — no inertia-ratio warning from this criterion;
- ratio > 10 — inertia mismatch warning;
- ratio > 30 — inertia-critical limiting factor.
These thresholds should be treated as screening criteria only. The acceptable ratio for a real servo axis must be confirmed from the selected motor and drive documentation and from the required dynamic response.
Limiting factor
The solver can report the following limiting-factor classifications:
- inertia-critical — inertia ratio is greater than 30;
- inertia-mismatch — inertia ratio is greater than 10;
- external-load-driven — the efficiency-adjusted external torque exceeds the modeled inertial acceleration torque;
- none — none of the above limiting-factor tests is active.
Safe, warning and invalid states
A safe interpretation means the entered peak and continuous motor torque limits are not exceeded and none of the implemented near-limit or inertia warnings is active.
A warning indicates limited margin or elevated inertia ratio. It does not mean the axis has failed, but it indicates that motor selection, motion profile or gearing deserves review.
The current JavaScript treats torque demand above the entered peak or continuous motor rating as invalid. In that state the primary numerical outputs are returned as null rather than being retained as an over-limit sizing result.
Passing these checks does not prove that the complete servo system is suitable. Motor speed capability, torque-speed characteristics, drive sizing, regenerative energy, mechanical stiffness, resonance, thermal environment and control performance remain separate checks.
Calculation example
Servo motor sizing example
Consider a repetitive servo axis with a gearbox. The objective is to calculate RMS torque and required peak torque and then compare them with the ratings of a candidate servo motor.
Input data
- Load inertia Jload = 0.040 kg·m2
- Motor inertia Jmotor = 0.0015 kg·m2
- Gear ratio i = 4.0
- Transmission efficiency η = 0.90
- Acceleration time tacc = 0.20 s
- Constant-speed time tconst = 0.80 s
- Deceleration time tdec = 0.20 s
- Idle time tidle = 0.40 s
- Maximum motor speed ωmax = 120 rad/s
- External torque Text = 1.20 N·m
- Motor continuous torque Tnom = 1.90 N·m
- Motor peak torque Tpeak,motor = 4.00 N·m
All example values are already expressed in SI units, so no additional unit conversion is required.
1. Angular acceleration
α = 120 / 0.20 = 600 rad/s2
2. Reflected inertia
Jload,ref = 0.040 / 42 = 0.0025 kg·m2
Jref = 0.0015 + 0.0025 = 0.0040 kg·m2
Inertia ratio = 0.0025 / 0.0015 = 1.67
3. Effective external torque
Text,eff = 1.20 / 0.90 = 1.333 N·m
4. Phase torques
Tacc = 0.0040 · 600 + 1.333 = 3.733 N·m
Tdec = -0.0040 · 600 + 1.333 = -1.067 N·m
Tconst = 1.333 N·m
Tidle = 0 N·m
5. Required peak torque
Tpeak,req = max(3.733, 1.067, 1.333) = 3.733 N·m
Peak utilization = 3.733 / 4.00 · 100% = 93.3%
6. RMS torque
tcycle = 0.20 + 0.80 + 0.20 + 0.40 = 1.60 s
TRMS = √[(3.7332·0.20 + 1.3332·0.80 + (-1.067)2·0.20 + 02·0.40) / 1.60]
TRMS = 1.665 N·m
Thermal utilization = 1.665 / 1.90 · 100% = 87.6%
7. Duty cycle
DC = (0.20 + 0.80 + 0.20) / 1.60 · 100% = 75.0%
Interpretation
The candidate motor remains below both entered torque limits: 3.733 N·m is below the 4.00 N·m peak rating and 1.665 N·m is below the 1.90 N·m continuous rating.
However, the calculator returns a warning because peak utilization exceeds 90% and thermal utilization exceeds 85%. The result therefore indicates a relatively small torque margin even though neither hard torque limit is exceeded.
This does not complete servo selection. The selected motor must still be checked at the actual operating speed using manufacturer data, together with drive capability, regeneration, mechanical dynamics and application-specific margins.
Assumptions and limitations
Assumptions and limitations
- The motion model consists of acceleration, constant-speed operation, deceleration and idle time.
- Angular acceleration is calculated only from ωmax/tacc. The same acceleration magnitude is used for the deceleration torque calculation. Therefore tdec changes RMS weighting and cycle duration but does not independently change the modeled deceleration magnitude.
- Load inertia is supplied by the user. The calculator does not derive inertia from mechanism mass or geometry.
- Load inertia is reflected through the gear ratio as Jload/i2.
- The input HTML labels the external torque as load-shaft torque, but the supplied JavaScript applies Text/η without dividing torque by the gear ratio. The implemented equation should therefore not be interpreted as a complete physical load-shaft-to-motor torque transformation.
- Transmission efficiency modifies the external torque term only. It does not modify the modeled inertial acceleration torque.
- Invalid, zero or greater-than-one transmission efficiency is replaced by η = 1 by the current solver.
- Idle torque is fixed at zero in the calculation. The holding-torque field present in the supplied input markup is not consumed by the supplied JavaScript.
- The motor-shaft-travel alternative input is not used by the supplied JavaScript. A positive direct maximum-speed value is required by the current solver.
- The separate candidate-motor maximum-speed field is not used for a speed-limit check.
- Motor inertia, continuous motor torque and peak motor torque are required by the current JavaScript even though some of these fields are presented as optional in the supplied input markup.
- Peak mechanical power is calculated using ωmax with each phase torque. It is a simplified indicator rather than a time-resolved power profile.
- The model does not include gearbox inertia, backlash, compliance, resonance, variable friction, changing process force or detailed gravity loading unless their effect has already been represented in the entered quantities.
- Thermal utilization is based only on RMS torque divided by entered continuous torque. Motor thermal time constants, ambient-temperature derating, cooling conditions and drive thermal limits are not modeled.
- The calculator does not evaluate the manufacturer's torque-speed envelope, regenerative braking capability, DC-bus limits, amplifier current limits or electrical power demand.
- Final servo selection should be verified using the motor and drive manufacturer's data for the actual speed, duty, installation conditions and required performance.